OYI 3436G4R

XPON ONU WIFI 6 DUAL BAND Optic Fiber

OYI 3436G4R

ONU product is the terminal equipment of a series of XPON which comply fully with ITU-G.984.1/2/3/4 standard and meet the energy-saving of G.987.3 protocol, ONU is based on mature and stable and high cost-effective GPON technology which adopts high-performance XPON REALTEK chipset and has high reliability, easy management, flexible configuration,robustness,good quality service guarantee(Qos).
 
This ONU supports IEEE802.11b/g/n/ac/ax, called WIFI6, concurrently, a WEB system provided simplifi  es the configuration of the WIFI and connects to INTERNET conveniently for users.
 
The ONU supports one pots for VOIP application.

Product Detail

FAQ

Product Tags

Product Features

1.comply fully with ITU-G.987.3 standard and OMCI full with ITU-G.988.

2.support downlink 2.488 Gbits/s rate and uplink 1.244 Gbits/s rate.

3.support download RS (248,216) FEC and uplink RS (248,232) FECCODEC.

4.support 32 TCONT and 256 GEM-port-ID or XGEM-port-ID.

5.support AES128 decryption/ encryption function.

6.support the PLOAM function of G.988 standard.

7.support Dying-Gasp check and report.

8.good interworking with the OLT from different manufacturerssuch as HuaWei , ZTE etc.

9.down-link LAN ports: 4*GE or 1*2.5GE+3*GE with auto-negotiation.

10.Support VLAN function.

11.support IEEE802.11b/g/n, IEEE802.11ac and IEEE802.11ax standard for WIFI.

12.antennas gain: 5DBi with external.

13.support: the Max PHY rate is 2975.5MbpsAX3000.

14.Multiple encryption methods: WPAWPA2WAP3..

15.one port for VOIP, SIP protocol optional.

16.one USB port.

17.better speed and lower latency gaming effects.

Specification

Tech Parameters

Description

Up-link interface

1 XPON interfaceSC single mode single fiber

RX 2.488 Gbits/s rate and TX 1.244 Gbits/s rate

Fiber typeSC/APC

Optical power0~4 dBm Sensitivity-28 dBm safety: ONU authentication mechanism

Wavelength(nm)

TX 1310 ± 10nmRX 1490 ± 3nm

Fiber connector

SC/APC or SC/UPC connector

Down-link data interface

4*GE or 1*2.5GE+3*GE auto-negotiation Ethernet interface, RJ45 interface

Indicator LED

10 pcsrefer to NO.6 definite of indicator LED

DC supply interface

Input+12V 1.0AfootprintDC0005 ø2.1MM

Power

≤10W

Operating temperature

-5+55℃

Humidity

1085%non-condensation

Storage temperature

-30+60℃

DimensionMM

185*125*32mmmainframe

Weight

0.5Kgmainframe

WIFI Characteristics

Tech Features

Description

Antenna

2.4G 2T3R 5G 2T2R external5DBI gain

Protocol

2.4G IEEE802.11b/g/n/ax 5G IEEE802.11ac/ax

Rate

2.4G Max PHY rate 573.5Mbp5G Max PHY rate 2402Mbps

Encryption methods

WEP,WPA2WPA3

Tx power

17.5dbm@-43DB DEVM HE40 MCS11

18dbm@-43DB DEVM HE80/160 MCS10/11

MU-MIMO

2.4G 802.11ax with OFDMA and MU-MIMO

5G 802.11ax with OFDMA and MU-MIMO ,802.11ac with wave2 MU-MIMO

Rx sensitivity

5G -45dBm@160Mhz bandwidth 1024QAM;

2.4G-51dBm@40Mhz bandwidth 1024QAM;

WPS function

Support

VOIP Technical features

Tech features

description

Voltage and Current Monitoring

The ONU continuously monitors the TIP, RING, and battery voltages and currents via an on-chip Monitor ADC

Power Monitoring and

Power Fault Detection

The ONU monitoring functions are used to continuously protect against excessive power conditions

Thermal Overload Shutdown

If the die temperature exceeds the maximum junction temperature threshold, the device will shut itself down

Default configuration

Protocol: SIP;

Codec type selection: G722, G729, G711A, G711U,

FAX: supportthe default configuration is disable;

Definition of Indicator LED

Symbol

Color

Meaning

PWR

Green

ON: successfully connect with power

OFF: fail to connect with power

PON

Green

ON: ONU port Link UP correctly

Flicker: PON registering

OFF: ONU ports link down faulty

LAN

Green

ON/ Flicker: Link up correctly

OFF: link down faulty

TEL

Green

ON: Register success

OFF: Register fail

2.4G/5G

Green

ON: WIFI is running

OFF: WIFI startup fail

LOS

Red

Flicker: Detected optical input

OFF: detected fiber to input

Packing List

Name

Quantity

Unit

XPON ONU

1

pcs

Supply Power

1

pcs

Manual & Warranty Card

1

pcs

Ordering Information

Model NO.

Function and Interface

Type of Fiber

Default

Communication Mode

OYI 346G4R

Wifi6  3000M AX   2.4G & 5G   4*4 MIMO

1 UP LINK

XPON, BOSA UPC/APC

HGU

OYI 3436G4R

wifi6  3000M AX   2.4G & 5G   1 VIOP

4*4 MIMO

1 UP LINK

XPON, BOSA UPC/APC

HGU

OYI 3426G4DER

wifi6   3000M AX     2.4G & 5G

1 WDM CATV 4*4MIMO

1 UP LINK

XPON, BOSA UPC/APC

HGU

OYI 34236G4DER

wifi6 3000M AX    2.4G & 5G    1 VIOP

1 WDM CATV 4*4 MIMO

1 UP LINK

XPON, BOSA UPC/APC

HGU

ONU Weight Table

Product form

Model NO.

Weigh t(kg)

Bare weight

kg)

Size

Carton

Product:

mm

Package (mm)

Carton size

Quantity

Weight (kg)

4LAN ONU

OYI 346G4R

0.40

0.20

168*110*3 6

215*200*4 3

49.5*48*37. 5

36

15.7

4LAN ONU

OYI 3436G4R

0.50

0.20

168*110*3 6

215*200*4 3

49.5*48*37. 5

28

15.4

4LAN ONU

3426G4DER

0.50

0.30

168.110*36

215*200*4 3

57.5*50.32. 5

32

17.2

4LAN ONU

34236G4DER

0.50

0.30

168.110*36

215*200*4 3

51*49*44

40

21.2

Products Recommended

  • OYI HD-08

    OYI HD-08

    OYI HD-08 is an ABS+PC plastic MPO box consists of box cassette and cover. It can load 1pc MTP/MPO adapter and 3pcs LC quad (or SC duplex) adapters without flange. It has fixing clip that suitable for installing in matched sliding fiber optic patch panel. There are push type operating handles at both side of MPO box. It is easy to install and disassemble. 

  • OYI-ODF-PLC-Series Type

    OYI-ODF-PLC-Series Type

    The PLC splitter is an optical power distribution device based on the integrated waveguide of quartz plate. It has the characteristics of small size, a wide working wavelength range, stable reliability, and good uniformity. It is widely used in PON, ODN, and FTTX points to connect between terminal equipment and the central office to achieve signal splitting.

    The OYI-ODF-PLC series 19′ rack mount type has 1×2, 1×4, 1×8, 1×16, 1×32, 1×64, 2×2, 2×4, 2×8, 2×16, 2×32, and 2×64, which are tailored to different applications and markets. It has a compact size with a wide bandwidth. All products meet ROHS, GR-1209-CORE-2001, and GR-1221-CORE-1999.

  • Simplex Patch Cord

    Simplex Patch Cord

    OYI fiber optic simplex patch cord, also known as a fiber optic jumper, is composed of a fiber optic cable terminated with different connectors at each end. Fiber optic patch cables are used in two major application areas: connecting computer workstations to outlets and patch panels or optical cross-connect distribution centers. OYI provides various types of fiber optic patch cables, including single-mode, multi-mode, multi-core, armored patch cables, as well as fiber optic pigtails and other special patch cables. For most of the patch cables, connectors such as SC, ST, FC, LC, MU, MTRJ, and E2000 (with APC/UPC polish) are available. Additionally, we also offer MTP/MPO patch cords.

  • OYI-FOSC-H5

    OYI-FOSC-H5

    The OYI-FOSC-H5 dome fiber optic splice closure is used in aerial, wall-mounting, and underground applications for the straight-through and branching splice of the fiber cable. Dome splicing closures are excellent protection of fiber optic joints from outdoor environments such as UV, water, and weather, with leak-proof sealing and IP68 protection.

  • Male to Female Type FC Attenuator

    Male to Female Type FC Attenuator

    OYI FC male-female attenuator plug type fixed attenuator family offers high performance of various fixed attenuation for industrial standard connections. It has a wide attenuation range, extremely low return loss, is polarization insensitive, and has excellent repeatability. With our highly integrated design and manufacturing capability, the attenuation of male-female type SC attenuator can also be customized to help our customers find better opportunities. Our attenuator complies with industry green initiatives,  such as ROHS.

  • Air Blowing Mini Optical Fibre Cable

    Air Blowing Mini Optical Fibre Cable

    The optical fiber is placed inside a loose tube made of high-modulus hydrolyzable material. The tube is then filled with thixotropic, water-repellent fiber paste to form a loose tube of optical fiber. A plurality of fiber optic loose tubes, arranged according to color order requirements and possibly including filler parts, are formed around the central non-metallic reinforcement core to create the cable core via SZ stranding. The gap in the cable core is filled with dry, water-retaining material to block water. A layer of polyethylene (PE) sheath is then extruded.
    The optical cable is laid by air blowing microtube. First, the air blowing microtube is laid in the outer protection tube, and then the micro cable is laid in the intake air blowing microtube by air blowing. This laying method has a high fiber density, which greatly improves the utilization rate of the pipeline. It is also easy to expand the pipeline capacity and diverge the optical cable.

If you're looking for a reliable, high-speed fibre optic cable solution, look no further than OYI. Contact us now to see how we can help you stay connected and take your business to the next level.

Facebook

YouTube

YouTube

Instagram

Instagram

LinkedIn

LinkedIn

tiktok

Tiktok

Tiktok

Whatsapp

+8618926041961

Email

sales@oyii.net