Central Loose Tube Armored Fiber Optic Cable

GYXTW

Central Loose Tube Armored Fiber Optic Cable

The two parallel steel wire strength members provide enough tensile strength. The uni-tube with special gel in the tube offers protection for the fibers. The small diameter and light weight make it easy to lay. The cable is anti-UV with a PE jacket, and is resistant to high and low temperature cycles, resulting in anti-aging and a longer lifespan.


Product Detail

FAQ

Product Tags

Product Features

The two parallel steel wire strength members provide enough tensile strength.

Unit-tube special gel in the tube offers protection for the fiber. Small diameter and light weight make it easy to lay, and it has excellent bending properties.

The outer sheath protects the cable from ultraviolet radiation.

Resistant to high and low temperature cycles, resulting in anti-aging and longer lifespan.

Loose-tube stranding cable core ensures the cable structure is stable.

Special designed compact structure is good at preventing loose tubes from shrinking.

PSP with enhanced moisture-proofing.

Optical Characteristics

Fiber Type Attenuation 1310nm MFD

(Mode Field Diameter)

Cable Cut-off Wavelength λcc(nm)
@1310nm(dB/KM) @1550nm(dB/KM)
G652D ≤0.35 ≤0.22 9.2±0.4 ≤1260
G657A1 ≤0.35 ≤0.22 9.2±0.4 ≤1260
G657A2 ≤0.35 ≤0.22 9.2±0.4 ≤1260
G655 ≤0.4 ≤0.23 (8.0-11)±0.7 ≤1450
50/125 ≤3.5 @850nm ≤1.5 @1300nm / /
62.5/125 ≤3.5 @850nm ≤1.5 @1300nm / /

Technical Parameters

Fiber Count Cable Diameter
(mm) ±0.5
Cable Weight
(kg/km)
Tensile Strength (N) Crush Resistance (N/100mm) Bending Radius (mm)
Long Term Short Term Long Term Short Term Static Dynamic
2-12 8.0 90 600 1500 300 1000 10D 20D
14-24 9.0 110 600 1500 300 1000 10D 20D

Application

Long distance communication and LAN.

Laying Method

Aerial, Duct

Operating Temperature

Temperature Range
Transportation Installation Operation
   -40℃~+70℃    -5℃~+45℃    -40℃~+70℃

Standard

YD/T 769-2010, IEC 60794

Packing And Mark

OYI cables are coiled on bakelite, wooden, or ironwood drums. During transportation, the right tools should be used to avoid damaging the package and to handle them with ease. Cables should be protected from moisture, kept away from high temperatures and fire sparks, protected from over-bending and crushing, and protected from mechanical stress and damage. It is not allowed to have two lengths of cable in one drum, and both ends should be sealed. The two ends should be packed inside the drum, and a reserve length of cable not less than 3 meters should be provided.

Loose Tube Non-metallic Heavy Type Rodent Protected

The color of cable markings is white. The printing shall be carried out at intervals of 1 meter on the outer sheath of the cable. The legend for the outer sheath marking can be changed according to the user's requests.

Test report and certification provided.

  • Products Recommended

    • OYI-ODF-R-Series Type

      OYI-ODF-R-Series Type

      The OYI-ODF-R-Series type series is a necessary part of the indoor optical distribution frame, specially designed for optical fiber communication equipment rooms. It has the function of cable fixation and protection, fiber cable termination, wiring distribution, and protection of fiber cores and pigtails. The unit box has a metal plate structure with a box design, providing a beautiful appearance. It is designed for 19″ standard installation, offering good versatility. The unit box has a complete modular design and front operation. It integrates fiber splicing, wiring, and distribution into one. Each individual splice tray can be pulled out separately, enabling operations inside or outside the box.

      The 12-core fusion splicing and distribution module plays the main role, with its function being splicing, fiber storage, and protection. A completed ODF unit will include adapters, pigtails, and accessories such as splice protection sleeves, nylon ties, snake-like tubes, and screws.

    • Micro Fiber Indoor Cable GJYPFV(GJYPFH)

      Micro Fiber Indoor Cable GJYPFV(GJYPFH)

      The structure of indoor optical FTTH cable is as follows: in the center is the optical communication unit.Two parallel Fiber Reinforced (FRP/Steel wire) are placed on the two sides. Then, the cable is completed with a black or colored  Lsoh Low Smoke Zero Halogen (LSZH/PVC) sheath.

    • OYI-ATB02C Desktop Box

      OYI-ATB02C Desktop Box

      OYI-ATB02C one ports terminal box is developed and produced by the company itself. The product’s performance meets the requirements of industry standards YD/T2150-2010. It is suitable for installing multiple types of modules and can be applied to the work area wiring subsystem to achieve dual-core fiber access and port output. It provides fiber fixing, stripping, splicing, and protection devices, and allows for a small amount of redundant fiber inventory, making it suitable for FTTD (fiber to the desktop) system applications. The box is made of high-quality ABS plastic through injection molding, making it anti-collision, flame retardant, and highly impact-resistant. It has good sealing and anti-aging properties, protecting the cable exit and serving as a screen. It can be installed on the wall.

    • Self-supporting  Figure 8  Fiber Optic Cable

      Self-supporting Figure 8 Fiber Optic Cable

      The 250um fibers are positioned in a loose tube made of high modulus plastic. The tubes are filled with a water-resistant filling compound. A steel wire is located in the center of the core as a metallic strength member. The tubes (and fibers) are stranded around the strength member into a compact and circular cable core. After an Aluminum (or steel tape) Polyethylene Laminate (APL) moisture barrier is applied around the cable core, this part of the cable, accompanied by the stranded wires as the supporting part, is completed with a polyethylene (PE) sheath to form a figure 8 structure. Figure 8 cables, GYTC8A and GYTC8S, are also available upon request. This type of cable is specifically designed for self-supporting aerial installation.

    • Double FRP reinforced non-metallic central bundle tube cable

      Double FRP reinforced non-metallic central bund...

      The structure of the GYFXTBY optical cable consists of multiple (1-12 cores) 250μm colored optical fibers (single-mode or multimode optical fibers) that are enclosed in a loose tube made of high-modulus plastic and filled with waterproof compound. A non-metallic tensile element (FRP) is placed on both sides of the bundle tube, and a tearing rope is placed on the outer layer of the bundle tube. Then, the loose tube and two non-metallic reinforcements form a structure that is extruded with high-density polyethylene (PE) to create an arc runway optical cable.

    • OYI-ODF-FR-Series Type

      OYI-ODF-FR-Series Type

      The OYI-ODF-FR-Series type optical fiber cable terminal panel is used for cable terminal connection and can also be used as a distribution box. It has a 19″ standard structure and is of the fixed rack-mounted type, making it convenient to operate. It is suitable for SC, LC, ST, FC, E2000 adapters, and more.

      The rack mounted optical cable terminal box is a device that terminates between the optical cables and the optical communication equipment. It has the functions of splicing, termination, storing, and patching of optical cables. The FR-series rack mount fiber enclosure provides easy access to fiber management and splicing. It offers a versatile solution in multiple sizes (1U/2U/3U/4U) and styles for building backbones, data centers, and enterprise applications.

    If you're looking for a reliable, high-speed fibre optic cable solution, look no further than OYI. Contact us now to see how we can help you stay connected and take your business to the next level.

    Facebook

    YouTube

    YouTube

    Instagram

    Instagram

    LinkedIn

    LinkedIn

    Whatsapp

    +8615361805223

    Email

    sales@oyii.net