Central Loose Tube Armored Fiber Optic Cable

GYXTW

Central Loose Tube Armored Fiber Optic Cable

The two parallel steel wire strength members provide enough tensile strength. The uni-tube with special gel in the tube offers protection for the fibers. The small diameter and light weight make it easy to lay. The cable is anti-UV with a PE jacket, and is resistant to high and low temperature cycles, resulting in anti-aging and a longer lifespan.


Product Detail

FAQ

Product Tags

Product Features

The two parallel steel wire strength members provide enough tensile strength.

Unit-tube special gel in the tube offers protection for the fiber. Small diameter and light weight make it easy to lay, and it has excellent bending properties.

The outer sheath protects the cable from ultraviolet radiation.

Resistant to high and low temperature cycles, resulting in anti-aging and longer lifespan.

Loose-tube stranding cable core ensures the cable structure is stable.

Special designed compact structure is good at preventing loose tubes from shrinking.

PSP with enhanced moisture-proofing.

Optical Characteristics

Fiber Type Attenuation 1310nm MFD

(Mode Field Diameter)

Cable Cut-off Wavelength λcc(nm)
@1310nm(dB/KM) @1550nm(dB/KM)
G652D ≤0.35 ≤0.22 9.2±0.4 ≤1260
G657A1 ≤0.35 ≤0.22 9.2±0.4 ≤1260
G657A2 ≤0.35 ≤0.22 9.2±0.4 ≤1260
G655 ≤0.4 ≤0.23 (8.0-11)±0.7 ≤1450
50/125 ≤3.5 @850nm ≤1.5 @1300nm / /
62.5/125 ≤3.5 @850nm ≤1.5 @1300nm / /

Technical Parameters

Fiber Count Cable Diameter
(mm) ±0.5
Cable Weight
(kg/km)
Tensile Strength (N) Crush Resistance (N/100mm) Bending Radius (mm)
Long Term Short Term Long Term Short Term Static Dynamic
2-12 8.0 90 600 1500 300 1000 10D 20D
14-24 9.0 110 600 1500 300 1000 10D 20D

Application

Long distance communication and LAN.

Laying Method

Aerial, Duct

Operating Temperature

Temperature Range
Transportation Installation Operation
   -40℃~+70℃    -5℃~+45℃    -40℃~+70℃

Standard

YD/T 769-2010, IEC 60794

Packing And Mark

OYI cables are coiled on bakelite, wooden, or ironwood drums. During transportation, the right tools should be used to avoid damaging the package and to handle them with ease. Cables should be protected from moisture, kept away from high temperatures and fire sparks, protected from over-bending and crushing, and protected from mechanical stress and damage. It is not allowed to have two lengths of cable in one drum, and both ends should be sealed. The two ends should be packed inside the drum, and a reserve length of cable not less than 3 meters should be provided.

Loose Tube Non-metallic Heavy Type Rodent Protected

The color of cable markings is white. The printing shall be carried out at intervals of 1 meter on the outer sheath of the cable. The legend for the outer sheath marking can be changed according to the user's requests.

Test report and certification provided.

  • Products Recommended

    • XPON ONU

      XPON ONU

      1G3F WIFI PORTS is designed as HGU (Home Gateway Unit) in different FTTH solutions; the carrier class FTTH application provides data service access. 1G3F WIFI PORTS is based on mature and stable, cost-effective XPON technology. It can switch automatically with EPON and GPON mode when it can access to the EPON OLT or GPON OLT.1G3F WIFI PORTS adopts high reliability, easy management, configuration flexibility and good quality of service (QoS) guarantees to meet the technical performance of the module of China Telecom EPON CTC3.0.1G3F WIFI PORTS is compliant with IEEE802.11n STD, adopts with 2×2 MIMO, the highest rate up to 300Mbps. 1G3F WIFI PORTS is fully compliant with technical regulations such as ITU-T G.984.x and IEEE802.3ah.1G3F WIFI PORTS is designed by ZTE chipset 279127.
    • Non-metallic Central Tube Access Cable

      Non-metallic Central Tube Access Cable

      The fibers and water-blocking tapes are positioned in a dry loose tube. The loose tube is wrapped with a layer of aramid yarns as a strength member. Two parallel fiber-reinforced plastics (FRP) are placed on the two sides, and the cable is completed with an outer LSZH sheath.
    • drop cable

      drop cable

      Drop Fiber Optic Cable 3.8 mm constructed one single strand of fiber with 2.4 mm loose tube, protected aramid yarn layer is for strength and physical support. Outer jacket made of HDPE materials that use in applications where smoke emission and toxic fumes could pose a risk to human health and essential equipment in the event of a fire.
    • Self-supporting  Figure 8  Fiber Optic Cable

      Self-supporting Figure 8 Fiber Optic Cable

      The 250um fibers are positioned in a loose tube made of high modulus plastic. The tubes are filled with a water-resistant filling compound. A steel wire is located in the center of the core as a metallic strength member. The tubes (and fibers) are stranded around the strength member into a compact and circular cable core. After an Aluminum (or steel tape) Polyethylene Laminate (APL) moisture barrier is applied around the cable core, this part of the cable, accompanied by the stranded wires as the supporting part, is completed with a polyethylene (PE) sheath to form a figure 8 structure. Figure 8 cables, GYTC8A and GYTC8S, are also available upon request. This type of cable is specifically designed for self-supporting aerial installation.
    • OYI-ODF-FR-Series Type

      OYI-ODF-FR-Series Type

      The OYI-ODF-FR-Series type optical fiber cable terminal panel is used for cable terminal connection and can also be used as a distribution box. It has a 19″ standard structure and is of the fixed rack-mounted type, making it convenient to operate. It is suitable for SC, LC, ST, FC, E2000 adapters, and more. The rack mounted optical cable terminal box is a device that terminates between the optical cables and the optical communication equipment. It has the functions of splicing, termination, storing, and patching of optical cables. The FR-series rack mount fiber enclosure provides easy access to fiber management and splicing. It offers a versatile solution in multiple sizes (1U/2U/3U/4U) and styles for building backbones, data centers, and enterprise applications.
    • OYI C Type Fast Connector

      OYI C Type Fast Connector

      Our fiber optic fast connector OYI C type is designed for FTTH (Fiber To The Home), FTTX (Fiber To The X). It is a new generation of fiber connector used in assembly. It can provide open flow and precast types, whose optical and mechanical specifications meet the standard optical fiber connector. It is designed for high quality and high efficiency for installation.

    If you're looking for a reliable, high-speed fibre optic cable solution, look no further than OYI. Contact us now to see how we can help you stay connected and take your business to the next level.

    Facebook

    YouTube

    YouTube

    Instagram

    Instagram

    LinkedIn

    LinkedIn

    tiktok

    Tiktok

    Tiktok

    Whatsapp

    +8618926041961

    Email

    sales@oyii.net