Bare Fiber Type Splitter

Optic Fiber PLC Splitter

Bare Fiber Type Splitter

A fiber optic PLC splitter, also known as a beam splitter, is an integrated waveguide optical power distribution device based on a quartz substrate. It is similar to a coaxial cable transmission system. The optical network system also requires an optical signal to be coupled to the branch distribution. The fiber optic splitter is one of the most important passive devices in the optical fiber link. It is an optical fiber tandem device with many input terminals and many output terminals, and is especially applicable to a passive optical network (EPON, GPON, BPON, FTTX, FTTH, etc.) to connect the ODF and the terminal equipment and to achieve the branching of the optical signal.


Product Detail

FAQ

Product Tags

OYI provide a highly precise bare fiber type PLC splitter for the construction of optical networks. The low requirements for placement position and environment, along with the compact micro design, make it especially suitable for installation in tiny rooms. It can be easily placed into different types of terminal boxes and distribution boxes, allowing for splicing and staying in tray without additional space reservation. It can be easily applied in PON, ODN, FTTx construction, optical network construction, CATV networks, and more.

The bare fiber tube type PLC splitter family includes 1x2, 1x4, 1x8, 1x16, 1x32, 1x64, 1x128, 2x2, 2x4, 2x8, 2x16, 2x32, 2x64, and 2x128, which are tailored to different applications and markets. They have a compact size with wide bandwidth. All products meet ROHS, GR-1209-CORE-2001, and GR-1221-CORE-1999 standards.

Product Features

Compact design.

Low insertion loss and low PDL.

High reliability.

High channel counts.

Wide operating wavelength: from 1260nm to 1650nm.

Large operating and temperature range.

Customized packaging and configuration.

Full Telcordia GR1209/1221 qualifications.

YD/T 2000.1-2009 Compliance (TLC Product Certificate Compliance).

Technical Parameters

Working Temperature: -40℃~80℃

FTTX (FTTP, FTTH, FTTN, FTTC).

FTTX networks.

Data Communication.

PON networks.

Fiber Type: G657A1, G657A2, G652D.

The RL of UPC is 50dB, the RL of APC is 55dB Note: UPC Connectors: IL add 0.2 dB, APC Connectors: IL add 0.3 dB.

7.Operation wavelength: 1260-1650nm.

Specifications

1×N (N>2) PLC (Without connector) Optical parameters
Parameters 1×2 1×4 1×8 1×16 1×32 1×64 1×128
Operation Wavelength (nm) 1260-1650
Insertion Loss (dB) Max 4 7.2 10.5 13.6 17.2 21 25.5
Return Loss (dB) Min 55 55 55 55 55 55 55
50 50 50 50 50 50 50
PDL (dB) Max 0.2 0.2 0.2 0.25 0.25 0.3 0.4
Directivity (dB) Min 55 55 55 55 55 55 55
WDL (dB) 0.4 0.4 0.4 0.5 0.5 0.5 0.5
Pigtail Length (m) 1.2 (±0.1) or customer specified
Fiber Type SMF-28e with 0.9mm tight buffered fiber
Operation Temperature (℃) -40~85
Storage Temperature (℃) -40~85
Dimension (L×W×H) (mm) 40×4x4 40×4×4 40×4×4 50×4×4 50×7×4 60×12×6 100*20*6
2×N (N>2) PLC (Without connector) Optical parameters
Parameters

2×4

2×8

2×16

2×32

2×64

2×128

Operation Wavelength (nm)

1260-1650

 
Insertion Loss (dB) Max

7.5

11.2

14.6

17.5

21.5

25.8

Return Loss (dB) Min

55

55

55

55

55

55

50

50

50

50

50

50

PDL (dB) Max

0.2

0.3

0.4

0.4

0.4

0.4

Directivity (dB) Min

55

55

55

55

55

55

WDL (dB)

0.4

0.4

0.5

0.5

0.5

0.5

Pigtail Length (m)

1.2 (±0.1) or customer specified

Fiber Type

SMF-28e with 0.9mm tight buffered fiber

Operation Temperature (℃)

 -40~85

Storage Temperature (℃)

 -40~85

Dimension (L×W×H) (mm)

40×4x4

40×4×4

60×7×4

60×7×4

60×12×6

100x20x6

Remark

The RL of UPC is 50dB, the RL of APC is 55dB.

Packaging Information

1x8-SC/APC as a reference. 

1 pc in 1 plastic box.

400 specific PLC splitters in carton box.

Outer carton box size: 47*45*55 cm, weight: 13.5kg.

OEM service available for mass quantity, can print logo on cartons.

Inner Packaging

Inner Packaging

Outer Carton

Outer Carton

Packaging Information
  • Products Recommended

    • OYI-FAT12A Terminal Box

      OYI-FAT12A Terminal Box

      The 12-core OYI-FAT12A optical terminal box performs in accordance with the industry-standard requirements of YD/T2150-2010. It is mainly used in the FTTX access system terminal link. The box is made of high-strength PC, ABS plastic alloy injection molding, which provides good sealing and aging resistance. In addition, it can be hung on the wall outdoors or indoors for installation and use.

    • Stay Rod

      Stay Rod

      This stay rod is used to connect the stay wire to the ground anchor, also known as the stay set. It ensures that the wire is firmly rooted to the ground and everything remains stable. There are two types of stay rods available in the market: the bow stay rod and the tubular stay rod. The difference between these two types of power-line accessories is based on their designs.

    • Zipcord Interconnect Cable GJFJ8V

      Zipcord Interconnect Cable GJFJ8V

      ZCC Zipcord Interconnect Cable uses 900um or 600um flame-retardant tight buffer fiber as an optical communication medium. The tight buffer fiber is wrapped with a layer of aramid yarn as strength member units, and the cable is completed with a figure 8 PVC, OFNP, or LSZH (Low Smoke, Zero Halogen, Flame-retardant) jacket.

    • OYI D Type Fast Connector

      OYI D Type Fast Connector

      Our fiber optic fast connector OYI D type is designed for FTTH (Fiber To The Home), FTTX (Fiber To The X). It is a new generation of fiber connector used in assembly and can provide open flow and precast types, with optical and mechanical specifications that meet the standard for optical fiber connectors. It is designed for high quality and high efficiency during installation.

    • MPO / MTP Trunk Cables

      MPO / MTP Trunk Cables

      Oyi MTP/MPO Trunk & Fan-out trunk patch cords provide an efficient way to install a large number of cables quickly. It also provides high flexibility on unplugging and re-use. It is especially suitable for the areas that require rapid deployment of high-density backbone cabling in data centers, and high fibre environments for high performance.

       

      MPO / MTP branch fan-out cable of us use high-density multi-core fiber cables and MPO / MTP connector

      through the intermediate branch structure to realize switching branch from the MPO / MTP to LC, SC, FC, ST, MTRJ and other common connectors. A variety of 4-144 single-mode and multi-mode optical cables can be used, such as common G652D/G657A1/G657A2 single-mode fiber, multimode 62.5/125, 10G OM2/OM3/OM4, or 10G multimode optical cable with high bending performance and so on .It is suitable for direct connection of MTP-LC branch cables–one end is 40Gbps QSFP+, and the other end is four 10Gbps SFP+. This connection decomposes one 40G into four 10G. In many existing DC environments, LC-MTP cables are used to support high-density backbone fibers between switches, rack-mounted panels, and main distribution wiring boards.

    • Male to Female Type SC Attenuator

      Male to Female Type SC Attenuator

      OYI SC male-female attenuator plug type fixed attenuator family offers high performance of various fixed attenuation for industrial standard connections. It has a wide attenuation range, extremely low return loss, is polarization insensitive, and has excellent repeatability. With our highly integrated design and manufacturing capability, the attenuation of male-female type SC attenuator can also be customized to help our customers find better opportunities. Our attenuator complies with industry green initiatives,  such as ROHS.

    If you're looking for a reliable, high-speed fibre optic cable solution, look no further than OYI. Contact us now to see how we can help you stay connected and take your business to the next level.

    Facebook

    YouTube

    YouTube

    Instagram

    Instagram

    LinkedIn

    LinkedIn

    Whatsapp

    +8618926041961

    Email

    sales@oyii.net