Iintambo zeSithungo seMPO / MTP

Intambo yePatch yeFiber ye-Optic

Iintambo zeSithungo seMPO / MTP

Iintambo ze-Oyi MTP/MPO Trunk kunye neFan-out trunk patch zibonelela ngendlela efanelekileyo yokufaka inani elikhulu leentambo ngokukhawuleza. Zikwabonelela ngokuguquguquka okuphezulu ekukhupheni nasekusebenziseni kwakhona. Zifaneleke ngakumbi kwiindawo ezifuna ukuthunyelwa ngokukhawuleza kweentambo zomqolo ezinoxinano olukhulu kwiindawo zedatha, kunye neendawo ezinefayibha ephezulu ukuze zisebenze kakuhle.

 

Intambo ye-MPO / MTP branch fan-out yethu isebenzisa iintambo zefayibha ezininzi ezinoxinano oluphezulu kunye nesixhumi se-MPO / MTP

ngokusebenzisa isakhiwo sesebe esiphakathi ukuze kuphunyezwe isebe elitshintshayo ukusuka kwi-MPO / MTP ukuya kwi-LC, SC, FC, ST, MTRJ kunye nezinye izihlanganisi eziqhelekileyo. Iintambo ezahlukeneyo ze-optical ze-4-144 zemowudi enye kunye nezemowudi ezininzi zingasetyenziswa, ezifana nefayibha yemowudi enye ye-G652D/G657A1/G657A2 eqhelekileyo, intambo ye-multimode 62.5/125, i-10G OM2/OM3/OM4, okanye intambo ye-optical ye-10G yemowudi eninzi enokugoba okuphezulu njalo njalo. Ifanelekile ukuqhagamshelwa ngokuthe ngqo kweentambo zesebe ze-MTP-LC–isiphelo esinye yi-40Gbps QSFP+, kwaye esinye isiphelo yi-10Gbps SFP+ ezine. Olu qhagamshelo lubolisa i-40G enye ibe yi-10G ezine. Kwiindawo ezininzi ze-DC ezikhoyo, iintambo ze-LC-MTP zisetyenziselwa ukuxhasa iifayibha ze-backbone ezinoxinano oluphezulu phakathi kweeswitshi, iiphaneli ezifakwe kwi-rack, kunye neebhodi zentambo eziphambili zokusasaza.


Iinkcukacha zeMveliso

FAQ

Iithegi zeMveliso

Inzuzo

Inkqubo efanelekileyo kunye nesiqinisekiso sovavanyo

Izicelo ezinoxinano olukhulu ukonga indawo yocingo

Ukusebenza kakuhle kwenethiwekhi ye-optical

Isicelo sesisombululo seentambo zedatha esifanelekileyo

Iimpawu zeMveliso

1. Kulula ukuyisebenzisa - Iinkqubo ezipheliswe ngumzi-mveliso zingonga ixesha lokufaka kunye nexesha lokulungisa inethiwekhi.

2. Ukuthembeka - sebenzisa izinto ezisemgangathweni ophezulu ukuqinisekisa umgangatho wemveliso.

3. Ifektri iphelile kwaye ivavanyiwe

4. Vumela ukufuduka okulula ukusuka kwi-10GbE ukuya kwi-40GbE okanye kwi-100GbE

5. Ilungele uqhagamshelo lweNethiwekhi ye-400G ekhawulezayo

6. Ukuphindaphinda okuhle kakhulu, ukutshintshiselana, ukuguguleka kunye nozinzo.

7. Yakhiwe ngezihlanganisi ezikumgangatho ophezulu kunye neefayibha ezisemgangathweni.

8. Isixhumi esisebenzayo: FC, SC, ST, LC njl.

9. Izinto zekhebula: PVC, LSZH, OFNR, OFNP.

10. Kukho imowudi enye okanye imowudi ezininzi, i-OS1, i-OM1, i-OM2, i-OM3, i-OM4 okanye i-OM5.

11. Uzinzo lokusingqongileyo.

Izicelo

Inkqubo yonxibelelwano.

2. Iinethiwekhi zonxibelelwano lwe-optical.

3. I-CATV, i-FTTH, i-LAN.

4. Inethiwekhi yokucubungula idatha.

5. Inkqubo yokudlulisela i-Optical.

6. Izixhobo zovavanyo.

QAPHELA: Singakunika intambo ethile yepetshi efunekayo kumthengi.

Iinkcukacha

Iziqhagamsheli zeMPO/MTP:

Uhlobo

Imowudi enye (ipolishi ye-APC)

Imowudi enye (ipolishi yePC)

Iimowudi ezininzi (ipolishi yePC)

Inani leeFayibha

4,8,12,24,48,72,96,144

Uhlobo lweFayibha

G652D,G657A1,njl.

G652D,G657A1,njl.

OM1, OM2, OM3, OM4, njl.

Ukulahleka Okuphezulu Kokufakwa (dB)

Ukulahleka okuphantsi/okuphantsi

Umgangatho

Ukulahleka okuphantsi/okuphantsi

Umgangatho

Ukulahleka okuphantsi/okuphantsi

Umgangatho

≤0.35dB

0.25dB eqhelekileyo

≤0.7dB

0.5dB eqhelekileyo

≤0.35dB

0.25dB eqhelekileyo

≤0.7dB

0.5dB eqhelekileyo

≤0.35dB

0.2dB eqhelekileyo

≤0.5dB

0.35dB eqhelekileyo

Ubude beWave obusebenzayo (nm)

1310/1550

1310/1550

850/1300

Ilahleko yokubuyisela (dB)

≥60

≥50

≥30

Ukuqina

≥ amaxesha angama-200

Ubushushu bokuSebenza (C)

-45~+75

Ubushushu bokugcina (C)

-45~+85

I-Conmector

I-MTP,MPO

Uhlobo lweConmector

I-MTP-Indoda, Ibhinqa; I-MPO-Indoda, Ibhinqa

I-Polarity

Uhlobo A, Uhlobo B, Uhlobo C

Iziqhagamsheli ze-LC/SC/FC:

Uhlobo

Imowudi enye (ipolishi ye-APC)

Imowudi enye (ipolishi yePC)

Iimowudi ezininzi (ipolishi yePC)

Inani leeFayibha

4,8,12,24,48,72,96,144

Uhlobo lweFayibha

G652D,G657A1,njl.

G652D,G657A1,njl.

OM1, OM2, OM3, OM4, njl.

Ukulahleka Okuphezulu Kokufakwa (dB)

Ukulahleka okuphantsi

Umgangatho

Ukulahleka okuphantsi

Umgangatho

Ukulahleka okuphantsi

Umgangatho

≤0.1dB

0.05dB eqhelekileyo

≤0.3dB

0.25dB eqhelekileyo

≤0.1dB

0.05dB eqhelekileyo

≤0.3dB

0.25dB eqhelekileyo

≤0.1dB

0.05dB eqhelekileyo

≤0.3dB

0.25dB eqhelekileyo

Ubude beWave obusebenzayo (nm)

1310/1550

1310/1550

850/1300

Ilahleko yokubuyisela (dB)

≥60

≥50

≥30

Ukuqina

≥ amaxesha angama-500

Ubushushu bokuSebenza (C)

-45~+75

Ubushushu bokugcina (C)

-45~+85

Amagqabaza: Zonke iintambo ze-MPO/MTP patch zineentlobo ezi-3 ze-polarity. Ziyi-Type A istrow type (1-to-1, ..12-to-12.), kunye ne-Type B ieCross type (1-to-12, ...12-to-1), kunye ne-Type C ieCross Pair type (1 to 2,...12 to 11)

Ulwazi lokuPakisha

I-LC -MPO 8F 3M njengesalathiso.

I-1.1 pc kwingxowa yeplastiki e-1.
Ii-2.500 pcs kwibhokisi yebhokisi.
3. Ubungakanani bebhokisi yebhokisi yangaphandle: 46*46*28.5cm, ubunzima: 19kg.
Inkonzo ye-4.OEM iyafumaneka ngobuninzi, inokuprinta ilogo kwiibhokisi.

Intambo yePatch yeFiber ye-Optic

Ukupakisha Kwangaphakathi

b
c

Ibhokisi yangaphandle

d
e

Iimveliso ezicetyiswayo

  • Ibhokisi yesiphelo se-OYI-FAT-H08B

    Ibhokisi yesiphelo se-OYI-FAT-H08B

    Le bhokisi isetyenziswa njengendawo yokuphela kwentambo ye-feeder ukuze idibane nentambo yokulahla kwinkqubo yenethiwekhi yonxibelelwano ye-FTTX. Idibanisa i-fiber splicing, splicing, distribution, storage kunye ne-cable connection kwiyunithi enye. Okwangoku, ibonelela ngokhuseleko oluqinileyo kunye nolawulo kwisakhiwo senethiwekhi ye-FTTX.
  • 310GR

    310GR

    Imveliso ye-ONU sisixhobo sokugcina soluhlu lwe-XPON oluhambelana ngokupheleleyo nomgangatho we-ITU-G.984.1/2/3/4 kwaye luhlangabezana nokonga amandla kweprotocol ye-G.987.3, isekelwe kubuchwepheshe be-GPON obuvuthiweyo nobuzinzileyo nobunexabiso eliphezulu obusebenzisa i-chipset ye-XPON Realtek esebenza kakhulu kwaye inokuthembeka okuphezulu, ulawulo olulula, uqwalaselo oluguquguqukayo, ukomelela, isiqinisekiso senkonzo esemgangathweni olungileyo (Qos). I-XPON inomsebenzi wokuguqula i-G / E PON, ofezekiswa yisoftware ecocekileyo.
  • Intambo yokufikelela kwiThubhu ePhakathi engeyiyo yesinyithi

    Intambo yokufikelela kwiThubhu ePhakathi engeyiyo yesinyithi

    Iifayibha kunye neeteyiphu ezithintela amanzi zibekwe kwityhubhu eyomileyo ekhululekileyo. Ityhubhu ekhululekileyo isongelwe ngomaleko weentambo ze-aramid njengelungu lokuqina. Iiplastiki ezimbini eziqinisiweyo zefayibha (FRP) ezihambelanayo zibekwe kumacala omabini, kwaye intambo igqityezelwe ngesheya yangaphandle ye-LSZH.
  • I-GYFC8Y53

    I-GYFC8Y53

    I-GYFC8Y53 yintambo ye-fiber optic ekhululekileyo esebenza kakhulu eyenzelwe usetyenziso lonxibelelwano olufuna amandla. Yakhiwe ngeetyhubhu ezikhululekileyo ezininzi ezizaliswe yi-compound ethintela amanzi kwaye ijikeleze ilungu lamandla, le ntambo iqinisekisa ukhuseleko oluhle kakhulu loomatshini kunye nozinzo lokusingqongileyo. Inee-fibers ezininzi ze-single-mode okanye ze-multimode optical, ezibonelela ngokudluliselwa kwedatha okuthembekileyo ngesantya esiphezulu kunye nokulahleka okuncinci kwesignali. Ngesheya yangaphandle eqinileyo engamelani ne-UV, ukukrala, kunye neekhemikhali, i-GYFC8Y53 ifanelekile ukufakwa ngaphandle, kubandakanya ukusetyenziswa emoyeni. Iimpawu zentambo ezithintela umlilo ziphucula ukhuseleko kwiindawo ezivalekileyo. Uyilo lwayo oluncinci luvumela ukuhanjiswa kunye nokufakwa okulula, kunciphisa ixesha lokufakwa kunye neendleko. Ilungele iinethiwekhi ezithatha ixesha elide, iinethiwekhi zokufikelela, kunye nokunxibelelana kweziko ledatha, i-GYFC8Y53 inikezela ngokusebenza okuzinzileyo kunye nokuqina, ihlangabezana nemigangatho yamazwe ngamazwe yonxibelelwano lwe-fiber optical.
  • I-Clevis ene-insulated yentsimbi

    I-Clevis ene-insulated yentsimbi

    I-Clevis efakwe i-insulation luhlobo olukhethekileyo lwe-clevis eyenzelwe ukusetyenziswa kwiinkqubo zokusasazwa kwamandla ombane. Yakhiwe ngezinto zokukhusela ezifana ne-polymer okanye i-fiberglass, ezigquma izinto zesinyithi ze-clevis ukuthintela ukuhanjiswa kombane ezisetyenziselwa ukuncamathisela ngokukhuselekileyo ii-conductor zombane, ezifana neentambo zombane okanye iintambo, kwii-insulators okanye kwezinye izixhobo kwi-utility poles okanye izakhiwo. Ngokuhlukanisa i-conductor kwi-clevis yesinyithi, ezi zinto zinceda ukunciphisa umngcipheko weempazamo zombane okanye ii-short circuits ezibangelwa kukudibana ngengozi ne-clevis. Ii-Spool Insulator Bracke zibalulekile ekugcineni ukhuseleko kunye nokuthembeka kweenethiwekhi zokusasazwa kwamandla.
  • 3436G4R

    3436G4R

    Imveliso ye-ONU sisixhobo sokugcina soluhlu lwe-XPON oluhambelana ngokupheleleyo nomgangatho we-ITU-G.984.1/2/3/4 kwaye luhlangabezana nokonga amandla kweprotocol ye-G.987.3, i-ONU isekelwe kubuchwepheshe be-GPON obuvuthiweyo nobuzinzileyo nobunexabiso eliphezulu obusebenzisa i-chipset ye-XPON REALTEK esebenza kakhulu kwaye inokuthembeka okuphezulu, ulawulo olulula, uqwalaselo oluguquguqukayo, ukuqina, isiqinisekiso senkonzo esemgangathweni (Qos). Le ONU ixhasa i-IEEE802.11b/g/n/ac/ax, ebizwa ngokuba yi-WIFI6, ngaxeshanye, inkqubo ye-WEB enikiweyo yenza kube lula ukucwangciswa kwe-WIFI kwaye iqhagamshela kwi-INTERNET ngokulula kubasebenzisi. I-ONU ixhasa imbiza enye yesicelo se-VOIP.

Ukuba ufuna isisombululo sentambo ye-fiber optic ethembekileyo nekhawulezayo, khangela i-OYI. Nxibelelana nathi ngoku ukuze ubone indlela esinokukunceda ngayo uhlale uqhagamshelene kwaye unyuse ishishini lakho liye kwinqanaba elilandelayo.

I-Facebook

iYouTube

iYouTube

I-Instagram

I-Instagram

I-LinkedIn

I-LinkedIn

i-tiktok

I-Tiktok

I-Tiktok

I-Whatsapp

+8618926041961

I-imeyile

sales@oyii.net