LGX Ntxig Cassette Hom Splitter

Optical Fiber PLC Splitter

LGX Ntxig Cassette Hom Splitter

Fiber optic PLC splitter, tseem hu ua beam splitter, yog ib qho integrated waveguide optical fais fab faib khoom siv raws li quartz substrate. Nws zoo ib yam li coaxial cable kis tau tus mob system. Lub optical network system kuj xav tau ib lub teeb liab optical kom txuas nrog rau ceg faib. Lub fiber optic splitter yog ib qho ntawm cov khoom siv passive tseem ceeb hauv optical fiber txuas. Nws yog ib qho optical fiber tandem ntaus ntawv nrog ntau lub tswv yim terminals thiab ntau lub tso zis terminals. Nws yog tshwj xeeb tshaj yog siv rau ib lub passive optical network (EPON, GPON, BPON, FTTX, FTTH, thiab lwm yam) los txuas ODF thiab cov khoom siv davhlau ya nyob twg thiab kom ua tiav qhov branching ntawm lub teeb liab optical.


Cov Lus Qhia Txog Khoom

Cov Lus Nug Feem Ntau

Cov Cim Npe Khoom

OYI muab LGX ntxig cassette-type PLC splitter uas meej heev rau kev tsim cov tes hauj lwm optical. Nrog rau qhov yuav tsum tau ua kom tsawg rau qhov chaw thiab ib puag ncig, nws cov qauv tsim cassette compact tuaj yeem yooj yim muab tso rau hauv lub thawv faib fiber optical, lub thawv sib txuas fiber optical, lossis txhua yam thawv uas tuaj yeem khaws qee qhov chaw. Nws tuaj yeem siv tau yooj yim hauv kev tsim FTTx, kev tsim kho network optical, CATV networks, thiab ntau ntxiv.

Cov tsev neeg LGX ntxig cassette-type PLC splitter suav nrog 1x2, 1x4, 1x8, 1x16, 1x32, 1x64, 2x2, 2x4, 2x8, 2x16, 2x32, 2x64, uas tau tsim los rau ntau daim ntawv thov thiab kev ua lag luam. Lawv muaj qhov loj me me nrog bandwidth dav. Txhua yam khoom ua tau raws li ROHS, GR-1209-CORE-2001, thiab GR-1221-CORE-1999 tus qauv.

Cov yam ntxwv ntawm cov khoom

Dav dav wavelength ua haujlwm: los ntawm 1260nm txog 1650nm.

Kev poob qis qis.

Kev poob qis ntsig txog polarization.

Tsim qauv me me.

Kev sib xws zoo ntawm cov channel.

Kev ntseeg siab thiab ruaj khov.

Dhau qhov kev xeem kev ntseeg siab GR-1221-CORE.

Ua raws li cov qauv RoHS.

Cov hom connectors sib txawv tuaj yeem muab tau raws li cov neeg siv khoom xav tau, nrog kev teeb tsa sai thiab kev ua haujlwm txhim khu kev qha.

Cov Kev Ntsuas Kev Txawj

Kub Ua Haujlwm: -40 ℃ ~ 80 ℃

FTTX (FTTP, FTTH, FTTN, FTTC).

FTTX tes hauj lwm.

Kev Sib Txuas Lus Txog Cov Ntaub Ntawv.

Cov tes hauj lwm PON.

Hom Fiber: G657A1, G657A2, G652D.

Kev xeem yuav tsum tau ua: RL ntawm UPC yog 50dB, APC yog 55dB; UPC Cov Khoom Txuas: IL ntxiv 0.2 dB, APC Cov Khoom Txuas: IL ntxiv 0.3 dB.

Dav dav wavelength ua haujlwm: los ntawm 1260nm txog 1650nm.

Cov Lus Qhia Tshwj Xeeb

1 × N (N> 2) PLC (Nrog rau qhov txuas) Cov kev teeb tsa kho qhov muag
Cov Kev Cai 1 × 2 1 × 4 1 × 8 1 × 16 1 × 32 1 × 64
Kev Ua Haujlwm Wavelength (nm) 1260-1650
Kev Ntxig Tsis Tau (dB) Max 4.2 7.4 10.7 13.8 17.4 21.2
Kev Poob Rov Qab (dB) Min 55 55 55 55 55 55
50 50 50 50 50 50
PDL (dB) Max 0.2 0.3 0.3 0.3 0.3 0.5
Kev Ncaj Ncees (dB) Min 55 55 55 55 55 55
WDL (dB) 0.4 0.4 0.4 0.5 0.5 0.5
Pigtail Ntev (m) 1.2 (± 0.1) lossis cov neeg siv khoom teev tseg
Hom Fiber SMF-28e nrog 0.9 hli nruj buffered fiber
Kev Ua Haujlwm Kub (℃) -40~85
Kub Cia (℃) -40~85
Qhov Loj ntawm Module (L × W × H) (hli) 130 × 100 x 25 130 × 100 x 25 130 × 100 x 25 130 × 100 x 50 130 × 100 × 102 130 × 100 × 206
2 × N (N> 2) PLC (Nrog rau qhov txuas) Cov kev teeb tsa kho qhov muag
Cov Kev Cai

2 × 4

2 × 8

2 × 16

2 × 32

Kev Ua Haujlwm Wavelength (nm)

1260-1650

Kev Ntxig Tsis Tau (dB) Max

7.7

11.4

14.8

17.7

Kev Poob Rov Qab (dB) Min

55

55

55

55

 

50

50

50

50

PDL (dB) Max

0.2

0.3

0.3

0.3

Kev Ncaj Ncees (dB) Min

55

55

55

55

WDL (dB)

0.4

0.4

0.5

0.5

Pigtail Ntev (m)

1.2 (± 0.1) lossis cov neeg siv khoom teev tseg

Hom Fiber

SMF-28e nrog 0.9 hli nruj buffered fiber

Kev Ua Haujlwm Kub (℃)

-40~85

Kub Cia (℃)

-40~85

Qhov Loj ntawm Module (L × W × H) (hli)

130 × 100 x 25

130 × 100 x 25

130 × 100 x 50

130 × 100 x 102

Lus Cim:Lub RL ntawm UPC yog 50dB, lub RL ntawm APC yog 55dB.

Cov Duab Khoom

1 * 4 LGX PLC Splitter

1 * 4 LGX PLC Splitter

LGX PLC Splitter

1 * 8 LGX PLC Splitter

LGX PLC Splitter

1 * 16 LGX PLC Splitter

Cov Ntaub Ntawv Txog Kev Ntim Khoom

1x16-SC/APC ua ib qho kev siv.

1 pc hauv 1 lub thawv yas.

50 PLC splitter tshwj xeeb hauv lub thawv ntawv.

Lub thawv sab nraud loj: 55 * 45 * 45 cm, hnyav: 10 kg.

Kev pabcuam OEM muaj rau qhov ntau thiab tsawg, tuaj yeem luam tawm lub logo ntawm cov thawv.

LGX-Ntxig-Cassette-Hom-Splitter-1

Ntim Sab Hauv

Lub thawv sab nraud

Lub thawv sab nraud

Cov Ntaub Ntawv Txog Kev Ntim Khoom

Cov Khoom Pom Zoo

  • OYI-FAT-10A Lub thawv davhlau ya nyob twg

    OYI-FAT-10A Lub thawv davhlau ya nyob twg

    Cov khoom siv no siv ua qhov chaw xaus rau lub cable feeder los txuas nrog lub cable poob hauv FTTx kev sib txuas lus network system. Kev sib txuas fiber ntau, kev faib tawm, kev faib tawm tuaj yeem ua tiav hauv lub thawv no, thiab lub sijhawm ntawd nws muab kev tiv thaiv zoo thiab kev tswj hwm rau lub tsev FTTx network.
  • FTTH Kev Ncua Nruj Clamp Tso Hlau Clamp

    FTTH Kev Ncua Nruj Clamp Tso Hlau Clamp

    FTTH suspension tension clamp fiber optic drop cable wire clamp yog ib hom hlau clamp uas siv dav los txhawb cov xov tooj poob xov hlau ntawm span clamps, drive hooks, thiab ntau yam khoom siv poob. Nws muaj lub plhaub, lub shim, thiab lub wedge nruab nrog lub hlau bail. Nws muaj ntau yam zoo, xws li kev tiv thaiv corrosion zoo, ruaj khov, thiab tus nqi zoo. Tsis tas li ntawd, nws yooj yim rau nruab thiab ua haujlwm yam tsis muaj cuab yeej, uas tuaj yeem txuag cov neeg ua haujlwm lub sijhawm. Peb muaj ntau yam qauv thiab cov lus qhia, yog li koj tuaj yeem xaiv raws li koj xav tau.
  • OYI-ATB08A Lub Thawv Rau Hauv Desktop

    OYI-ATB08A Lub Thawv Rau Hauv Desktop

    Lub thawv OYI-ATB08A 8-chaw nres nkoj desktop yog tsim thiab tsim los ntawm lub tuam txhab nws tus kheej. Cov khoom ua tau zoo raws li cov qauv kev lag luam YD/T2150-2010. Nws tsim nyog rau kev teeb tsa ntau hom modules thiab tuaj yeem siv rau thaj chaw ua haujlwm wiring subsystem kom ua tiav dual-core fiber nkag thiab qhov chaw tso zis. Nws muab cov khoom siv kho fiber, stripping, splicing, thiab kev tiv thaiv, thiab tso cai rau me ntsis ntawm cov khoom siv fiber redundant, ua rau nws tsim nyog rau FTTD (fiber rau lub desktop) daim ntawv thov system. Lub thawv yog ua los ntawm cov yas ABS zoo los ntawm kev txhaj tshuaj molding, ua rau nws tiv thaiv kev sib tsoo, hluav taws kub retardant, thiab tiv taus kev cuam tshuam heev. Nws muaj cov khoom zoo sealing thiab tiv thaiv kev laus, tiv thaiv cov cable tawm thiab ua haujlwm ua lub vijtsam. Nws tuaj yeem ntsia tau rau ntawm phab ntsa.
  • OYI-FAT16D Lub thawv davhlau ya nyob twg

    OYI-FAT16D Lub thawv davhlau ya nyob twg

    Lub thawv 16-core OYI-FAT16D optical terminal ua haujlwm raws li cov qauv kev lag luam ntawm YD / T2150-2010. Nws feem ntau yog siv rau hauv FTTX nkag mus rau qhov system terminal link. Lub thawv yog ua los ntawm cov khoom siv PC muaj zog, ABS yas alloy txhaj tshuaj molding, uas muab kev sib khi zoo thiab kev laus tsis kam. Tsis tas li ntawd, nws tuaj yeem dai rau ntawm phab ntsa sab nraum zoov lossis sab hauv tsev rau kev teeb tsa thiab siv.
  • OYI-FOSC-D108M-B PLC Hom

    OYI-FOSC-D108M-B PLC Hom

    Lub OYI-FOSC-D108M-B Hom dome fiber optic splice kaw yog siv rau hauv huab cua, phab ntsa-mounting, thiab hauv av daim ntawv thov rau txoj kab ncaj thiab ceg ntawm cov fiber cable. Dome splicing kaw yog kev tiv thaiv zoo heev ntawm cov pob qij txha fiber optic los ntawm cov chaw sab nraum zoov xws li UV, dej, thiab huab cua, nrog rau kev sib khi tsis xau thiab IP68 kev tiv thaiv. Lub kaw muaj 6 lub qhov rooj nkag qhov rooj ntawm qhov kawg. Lub plhaub ntawm cov khoom yog ua los ntawm PP + ABS khoom. Lub plhaub thiab lub hauv paus raug kaw los ntawm kev nias cov roj hmab silicone nrog lub clamp faib. Cov qhov rooj nkag tau kaw los ntawm kev sib khi tshuab. Cov kaw tuaj yeem qhib dua tom qab raug kaw thiab rov siv dua yam tsis tau hloov cov khoom sib khi. Lub kaw lub ntsiab tsim suav nrog lub thawv, splicing, thiab nws tuaj yeem teeb tsa nrog cov adapters thiab optical splitters.
  • Kev Sib Txuas Clamp PA2000

    Kev Sib Txuas Clamp PA2000

    Lub clamp cable anchoring no zoo thiab ruaj khov. Cov khoom no muaj ob ntu: ib qho yog hlau stainless hlau thiab nws cov khoom tseem ceeb, lub cev nylon uas muaj zog uas tsis hnyav thiab yooj yim nqa mus rau sab nraum zoov. Cov khoom siv lub cev ntawm lub clamp yog yas UV, uas yog tus phooj ywg thiab muaj kev nyab xeeb thiab siv tau rau hauv thaj chaw sov. Lub clamp FTTH anchor no tsim los kom haum rau ntau yam qauv cable ADSS thiab tuaj yeem tuav cov cables nrog txoj kab uas hla ntawm 11-15 hli. Nws yog siv rau cov cables fiber optic tuag-kawg. Kev teeb tsa lub cable FTTH drop yog qhov yooj yim, tab sis kev npaj ntawm lub cable optical yog qhov yuav tsum tau ua ntej txuas nws. Lub qhov qhib-khawm tus kheej ua rau kev teeb tsa ntawm cov ncej fiber yooj yim dua. Lub clamp FTTX optical fiber thiab cov hlua khi cable drop muaj nyob rau cais lossis ua ke ua ke. FTTX drop cable anchor clamps tau dhau qhov kev sim tensile thiab tau sim hauv qhov kub ntawm -40 txog 60 degrees Celsius. Lawv kuj tau dhau qhov kev sim kub cycling, kev sim laus, thiab kev sim corrosion.

Yog tias koj tab tom nrhiav kev daws teeb meem fiber optic cable uas txhim khu kev qha thiab ceev ceev, tsis txhob nrhiav ntxiv lawm tsuas yog OYI xwb. Tiv tauj peb tam sim no kom pom tias peb tuaj yeem pab koj txuas lus li cas thiab coj koj txoj kev lag luam mus rau qib tom ntej.

Facebook

YouTube

YouTube

Instagram

Instagram

LinkedIn

LinkedIn

tiktok

Tiktok

Tiktok

Whatsapp

+8618926041961

Email

sales@oyii.net