3213GER

XPON NYOB RAU

3213GER

Cov khoom ONU yog cov khoom siv kawg ntawm XPON uas ua raws li ITU-G.984.1 / 2/3/4 tus qauv thiab ua tau raws li kev txuag hluav taws xob ntawm G.987.3 protocol, ONU yog raws li kev paub tab thiab ruaj khov thiab pheej yig GPON thev naus laus zis uas siv cov txheej txheem XPON Realtek chip teeb tsa siab thiab muaj kev ntseeg siab, kev tswj hwm yooj yim, kev teeb tsa yooj yim, kev ruaj khov, kev pabcuam zoo (Qos).
ONU txais RTL rau WIFI daim ntawv thov uas txhawb nqa IEEE802.11b / g / n tus qauv tib lub sijhawm, lub WEB system muab ua kom yooj yim rau kev teeb tsa ntawm ONU thiab txuas rau INTERNET yooj yim rau cov neeg siv.
XPON muaj G / E PON kev hloov pauv sib koom ua ke, uas tau pom los ntawm software ntshiab.
ONU txhawb nqa ib lub lauj kaub rau VOIP daim ntawv thov.


Cov Khoom Qhia Txog Khoom

Cov Lus Nug Feem Ntau

Cov Cim Npe Khoom

Cov yam ntxwv ntawm cov khoom

1. ua raws li ITU-G.984.1/2/3/4 tus qauv thiab G.987.3 protocol tag nrho.

2. txhawb nqa downlink 2.488 Gbits / s tus nqi thiab uplink 1.244 Gbits / s tus nqi.

3. txhawb nqa bidirectional FEC thiab RS (255,239) FEC CODEC.

4. txhawb nqa 32 TCONT thiab 256 GEMPORT.

5. txhawb nqa AES128 decryption function ntawm G.984 tus qauv.

6. txhawb nqa SBA thiab DBA dynamically broadband allocation.

7. txhawb nqa PLOAM kev ua haujlwm ntawm G.984 tus qauv.

8. txhawb nqa Dying-Gasp kev kuaj xyuas thiab tshaj tawm.

9. kev txhawb nqa synchronousEthernet.

10. kev sib koom tes zoo nrog OLT los ntawm ntau lub tuam txhab tsim khoom, xws li huawei, Realtek, Cortina thiab lwm yam.

11. qhov txuas LAN down-link: 1 * 10/100M nrog kev sib tham pib 1 * 10/100 / 1000M nrog kev sib tham pib.

12. txhawb nqa lub zog ceeb toom ONU.

13. Txhawb nqa VLAN kev ua haujlwm.

14. hom kev ua haujlwm: SFU lossis HGU xaiv.

15. txhawb nqa IEEE802.11b/g/n tus qauv rau WIFI.

16. ob lub antennas: lub thawv sab nraud nrog 5DBi.

17. kev txhawb nqa ntawm 300Mbps PHY tus nqi.

18. kev txhawb nqa ntau SSID.

19. Ntau txoj kev encryption: WFA, WPA, WPA2, WAPI.

20. ib qho chaw nres nkoj rau VOIP, txhawb nqa H.248, SIP raws tu qauv xaiv tau.

Cov Lus Qhia Tshwj Xeeb

 
 
 

Cov txheej txheem thev naus laus zis

Kev piav qhia

1

Uplink interface

1 XPON interface, SC ib hom ib qho fiber RX 2.488 Gbits / s tus nqi thiab TX

1.244 Gbits/s tus nqi Fiber hom: SC/APC

Lub zog kho qhov muag: 0 ~ 4 dBm Kev rhiab heev: -28 dBm kev nyab xeeb: ONU authentication mechanism

2

Qhov ntev ntawm lub zog (nm)

TX 1310nm, RX 1490nm

3

Cov khoom siv fiber ntau

SC/APC txuas

4

Down-link data interface

1 * 10/100Mbps thiab 1 * 10/100/1000M pib-kev sib tham Ethernet interface, RJ45 interface

5

LED qhia

7 pcs, xa mus rau NO.6 txhais ntawm qhov qhia LED

6

DC khoom siv interface

tswv yim + 12V 1A, qhov chaw taw qhia: DC0005 ø2.1MM

7

Lub zog

≤5W

8

Kub ua haujlwm

-5 ~ + 55 ℃

9

Av noo

10 ~ 85% (tsis yog condensation)

10

Kub cia khoom

-30 ~ + 70 ℃

11

Qhov Loj (MM)

155 * 92 * 32mm (lub cev loj)

12

Qhov hnyav

0.38Kg (lub cev tseem ceeb)

 

1. Cov yam ntxwv ntawm WIFI

 

Cov yam ntxwv ntawm kev siv tshuab

Kev piav qhia

1

Kav hlau txais xov

Hom 2T2R

5DBI nce, Zaus: 2.4G

2

Tus nqi

WIFI4 wireless ceev ntawm 300Mbps, nrog 13 txoj kev;

3

Cov txheej txheem encryption

WFA, WPA, WPA2, WAPI

4

Lub zog kis tau

WiFi4 17dBm;

5

Kev txais kev rhiab heev

WiFi4-59dBm @ channel 11, MCS7

6

WPS feature

kev txhawb nqa

 

2. Cov yam ntxwv ntawm VOIP

Cov yam ntxwv ntawm kev siv tshuab

Kev piav qhia

1

Voltage thiab Tam Sim No

Kev saib xyuas

Tus saib xyuas tas li ntawm TIP, RING, thiab roj teeb voltages thiab currents ntawm on-chip Monitor ADC.

2

Kev Saib Xyuas Fais Fab thiab Kev Tshawb Pom Qhov Teeb Meem Fais Fab

Cov haujlwm saib xyuas yog siv los tiv thaiv tsis tu ncua tiv thaiv cov xwm txheej fais fab ntau dhau

3

Thermal Overload

Kaw

Yog tias qhov kub ntawm lub pwm kub tshaj qhov kub siab tshaj plaws ntawm qhov sib txuas, lub cuab yeej yuav kaw nws tus kheej.

4

Kev teeb tsa ua ntej

Cov txheej txheem suab: SIP; Media stream encoding: G722, G729, G711A, G711U, fax: kaw;

   

Cov txheej txheem suab: SIP; Media stream encoding: G722, G729, G711A, G711U, fax: kaw;

   

Cov txheej txheem suab: SIP; Media stream encoding: G722, G729, G711A, G711U, fax: kaw;

Kev Teeb tsa thiab Kev Pib

1. Muab SC/APC fiber patch cord los yog pigtail rau hauv PON interface ntawm cov khoom.

2. Siv lub network untwised-pair los ntawmkev sib txuas lus cov khoom siv rau Lan Interface ntawm cov khoom, LAN interface ntawm cov khoom no txhawb nqa AUTO-MDIX function.

3. Muab lub zog rau cov khoom, thov siv lub DC ntsaws ntawm lub adapter los txuas nrog lub DC qhov (socket) ntawm cov khoom, thiab lub AC ntsaws ntawm lub hwj chim adapter yuav tsum tau ntsaws rau hauv lub AC qhov (socket).

4. Lub hwj chim yuav txuas nrog tau zoo yog tias lub cim qhia PWR qhib, lub kaw lus yuav pib ua haujlwm, thiab tom qab ntawd, tos kom tiav qhov kev pib ua haujlwm.

Kev txhais ntawm qhov qhia LED

Lub Cim

Xim

Lub ntsiab lus

PWR

Ntsuab

ON: txuas tau zoo nrog lub hwj chim OFF: txuas tsis tau nrog lub hwj chim

PON

Ntsuab

ON: ONU qhov chaw nres nkoj txuas kom raug Flicker: PON sau npe OFF: ONU qhov chaw nres nkoj txuas

qhov txuas tsis zoo

LAN

Ntsuab

ON: Txuas kom raug Flicker: cov ntaub ntawv xa tawm OFF: txuas tsis ua haujlwm

Cov lauj kaub

Ntsuab

ON: Kev sau npe ua tiav OFF: Kev sau npe ua tsis tiav

WIFI

Ntsuab

ON: WIFI khiav OFF: WIFI pib tsis ua haujlwm

LOS

Liab

Flicker: tsis txuas nrog PON chaw nres nkoj OFF: pom cov fiber rau cov tswv yim

Daim ntawv teev cov khoom ntim khoom

Lub Npe

Qhov ntau

Chav tsev

XPON ONU

1

cov khoom

Muab Fais Fab

1

cov khoom

Phau Ntawv Qhia & Daim Npav Pov Thawj

1

cov khoom

Cov ntaub ntawv xaj khoom ONU Qhov hnyav

Khoom

Qauv

Kev Ua Haujlwm thiab LAN

Cov Chaw Nres LAN

Hom Fiber

Lub sijhawm pib

Hom

323GER

1GE+1FE 2.4 G WIFI 1VOIP

2LAN, 1GE + 1FE RJ45

1 UP LINK XPON, BOSA

UPC/APC

HGU

321GER

1GE + 1FE 2.4 G WIFI

2LAN, 1GE + 1FE RJ45

1 UP LINK XPON, BOSA

UPC/APC

HGU

3213GER

1GE + 1FE 2.4 G WIFI

1 VOIP

2LAN, 1GE + 1FE RJ45

1 UP LINK XPON, BOSA

UPC/APC

HGU

3212GDER

 

1GE + 1FE 2.4 G WIFI1 WDM CATV

2LAN, 1GE + 1FE RJ45

 

1 UP LINK XPON, BOSA

UPCIAPC

HGU

32123GDER

1GE+1FE2.4 G WIF!1 VOIP 1 WDM CATV

2LAN, 1GE + 1FE RJ45

1 UP LINK XPON, B OSA

UPCIAPC

HGU

Qhov hnyav ntawm ONU

Daim Ntawv Khoom

Qauv Khoom

Qhov hnyav

(kg)

Liab qab

Qhov hnyav

kg)

Qhov Loj

Lub thawv

Kev piav qhia txog khoom

Khoom:

mm)

Pob khoom

(hli)

Qhov loj ntawm lub thawv: (cm)

Tus lej

Qhov hnyav

(kg)

2 Chaw nres nkoj ONU

323GER

0.3

0.15

108 * 85 * 25

146 * 117 * 66

45.9 * 42 * 34.2

40

13.6

1GE 1FE

VOIP

2 Chaw nres nkoj ONU

321GER

0.38

0.18

155 * 92 * 32

220 * 160 * 38

49.5 * 48 * 37.5

50

20.3

1GE 1FE

WIFI

2 Chaw nres nkoj ONU

3213GER

0.38

0.18

155 * 92 * 32

220 * 160 * 38

49.5 * 48 * 37.5

50

20.3

1GE 1FE

WIFI, VOIP

2 Chaw nres nkoj ONU

3212GDER

0.38

0.18

155 * 92 * 32

220 * 160 * 38

49.5 * 48 * 37.5

50

20.3

1GE 1FE WIFI, CATV

2 Chaw nres nkoj ONU

32123GDER

0.38

0.18

155 * 92 * 32

220 * 160 * 38

49.5 * 48 * 37.5

50

20.3

1GE 1FE

WIFI, VOIP,

CATV

Cov Khoom Pom Zoo

  • OYI-FAT12B Lub thawv davhlau ya nyob twg

    OYI-FAT12B Lub thawv davhlau ya nyob twg

    Lub thawv OYI-FAT12B optical terminal box 12-core ua haujlwm raws li cov qauv kev lag luam ntawm YD/T2150-2010. Nws feem ntau yog siv rau hauv FTTX access system terminal link. Lub thawv yog ua los ntawm cov khoom siv PC muaj zog, ABS yas alloy txhaj tshuaj molding, uas muab kev sib khi zoo thiab kev laus tsis kam. Tsis tas li ntawd, nws tuaj yeem dai rau ntawm phab ntsa sab nraum zoov lossis sab hauv tsev rau kev teeb tsa thiab siv. Lub thawv OYI-FAT12B optical terminal muaj kev tsim sab hauv nrog ib txheej txheej, faib ua thaj chaw faib khoom, kev ntxig cable sab nraum zoov, fiber splicing tais, thiab FTTH poob optical cable cia. Cov kab fiber optic yog qhov tseeb heev, ua rau nws yooj yim rau kev khiav lag luam thiab tswj. Muaj 2 lub qhov cable hauv qab lub thawv uas tuaj yeem tso 2 sab nraum zoov optical cables rau kev sib tshuam ncaj qha lossis sib txawv, thiab nws kuj tuaj yeem tso 12 FTTH poob optical cables rau kev sib txuas kawg. Lub tais fiber splicing siv daim ntawv tig thiab tuaj yeem teeb tsa nrog lub peev xwm ntawm 12 cores kom haum rau kev nthuav dav ntawm lub thawv siv.
  • OYI-FAT16D Lub thawv davhlau ya nyob twg

    OYI-FAT16D Lub thawv davhlau ya nyob twg

    Lub thawv 16-core OYI-FAT16D optical terminal ua haujlwm raws li cov qauv kev lag luam ntawm YD / T2150-2010. Nws feem ntau yog siv rau hauv FTTX nkag mus rau qhov system terminal link. Lub thawv yog ua los ntawm cov khoom siv PC muaj zog, ABS yas alloy txhaj tshuaj molding, uas muab kev sib khi zoo thiab kev laus tsis kam. Tsis tas li ntawd, nws tuaj yeem dai rau ntawm phab ntsa sab nraum zoov lossis sab hauv tsev rau kev teeb tsa thiab siv.
  • OYI-F401

    OYI-F401

    Lub vaj huam sib luag optic muab kev sib txuas ceg rau kev xaus fiber. Nws yog ib chav tsev sib xyaw ua ke rau kev tswj hwm fiber, thiab siv tau ua lub thawv faib khoom. Nws muab faib ua hom kho thiab hom swb-tawm. Lub luag haujlwm ntawm cov khoom siv no yog los kho thiab tswj cov xov hlau fiber optic hauv lub thawv nrog rau kev tiv thaiv. Lub thawv xaus fiber optic yog modular yog li lawv siv tau rau koj cov kab ke uas twb muaj lawm yam tsis muaj kev hloov kho lossis ua haujlwm ntxiv. Haum rau kev teeb tsa FC, SC, ST, LC, thiab lwm yam adapters, thiab haum rau fiber optic pigtail lossis lub thawv yas hom PLC splitters.
  • Fiber Optic Cleaner Cwj mem 1.25mm Hom

    Fiber Optic Cleaner Cwj mem 1.25mm Hom

    Tus cwj mem ntxuav fiber optic ib-nias rau 1.25mm LC/MU Connectors (800 zaug ntxuav) Tus cwj mem ntxuav fiber optic ib-nias yooj yim siv thiab siv tau los ntxuav LC/MU connectors thiab cov collars 1.25mm uas raug tso tawm hauv lub adapter fiber optic cable. Tsuas yog ntxig lub tshuab ntxuav rau hauv lub adapter thiab thawb nws kom txog thaum koj hnov ​​​​​​lub suab "nias". Lub tshuab ntxuav thawb siv lub tshuab thawb kom thawb daim kab xev ntxuav qib optical thaum tig lub taub hau ntxuav kom ntseeg tau tias qhov chaw kawg ntawm fiber zoo tab sis maj mam ntxuav.
  • Hom FC

    Hom FC

    Fiber optic adapter, qee zaum kuj hu ua coupler, yog ib lub cuab yeej me me uas tsim los xaus lossis txuas cov cables fiber optic lossis cov connectors fiber optic ntawm ob kab fiber optic. Nws muaj lub tes tsho interconnect uas tuav ob lub ferrules ua ke. Los ntawm kev txuas ob lub connectors, fiber optic adapters tso cai rau cov teeb pom kev zoo kom xa mus rau lawv qhov siab tshaj plaws thiab txo qhov poob ntau li ntau tau. Tib lub sijhawm, fiber optic adapters muaj qhov zoo ntawm qhov poob qis, kev sib pauv zoo, thiab kev rov ua dua. Lawv siv los txuas cov connectors fiber optical xws li FC, SC, LC, ST, MU, MTRJ, D4, DIN, MPO, thiab lwm yam. Lawv siv dav hauv cov khoom siv sib txuas lus fiber optical, cov khoom siv ntsuas, thiab lwm yam. Kev ua tau zoo ruaj khov thiab txhim khu kev qha.
  • OPGW Optical Av Hlau

    OPGW Optical Av Hlau

    Lub raj nruab nrab OPGW yog ua los ntawm cov hlau tsis xeb (yeeb nkab txhuas) fiber unit nyob rau hauv nruab nrab thiab cov hlau txhuas clad hlau stranding txheej txheem nyob rau hauv lub txheej sab nraud. Cov khoom no yog tsim rau kev ua haujlwm ntawm ib lub raj optical fiber unit.

Yog tias koj tab tom nrhiav kev daws teeb meem fiber optic cable uas txhim khu kev qha thiab ceev ceev, tsis txhob nrhiav ntxiv lawm tsuas yog OYI xwb. Tiv tauj peb tam sim no kom pom tias peb tuaj yeem pab koj txuas lus li cas thiab coj koj txoj kev lag luam mus rau qib tom ntej.

Facebook

YouTube

YouTube

Instagram

Instagram

LinkedIn

LinkedIn

tiktok

Tiktok

Tiktok

Whatsapp

+8618926041961

Email

sales@oyii.net